Electrical Data
Capacitance range: 0.68 µF to 75 µF
Rated voltages: 230VAC, 275VAC, 305VAC, 350VAC, 440VAC
Capacitance tolerances: ±20%, ±10%, ±5%
Operating temperature range: -55°C to +105°C
Climatic test category: 55/105/56 in accordance with IEC
Insulation resistance at +20°C:
> 30000 sec (MΩ x µF)
Measuring voltage: 100V/1 min.
Test voltage: 1.5 U
rDC, 10sec
Test specifications: In accordance with IEC 61071 and 60068
Reliability: Operational life > 60000 hours at U
r. Failure rate < 10 fit (0.5 x U
r and 40°C)
Dissipation factors at +20°C: tanδ
at f |
PCM 27.5 |
PCM 37.5 |
PCM 52.5 |
1 kHz
10 kHz |
< 5 x 10-4
< 20 x 10-4 |
< 10 x 10-4
< 45 x 10-4 |
< 15 x 10-4
< 90 x 10-4 |
Reference frequency 1 kHz in accordance with IEC 60384-1
Voltage derating: A voltage derating factor must be applied according to the graph:
Maximum pulse rise time:
PCM |
max. pulse rise time V/µsec at TA < 40°C |
230VAC |
275VAC |
305VAC |
350VAC |
440VAC |
27.5
37.5
52.5 |
45
20
10 |
55
30
13 |
68
35
15 |
100
50
25 |
110
70
40 |
Mechanical Tests
Pull test on pins: 10 N in direction of pins according to IEC 60068-2-21
Vibration: 6 hours at 10...2000Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec
2 in accordance with IEC 60068-2-29
Packing
Available taped and reeled up to and including case size 15x26x31.5 / PCM 27.5mm.